MAX1693/(MAX1693H)/MAX1694
USB Current-Limited Switches
with Fault Blanking
2
_______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VIN = +5V, TA = 0°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
IN, ON (ON), FAULT to GND....................................-0.3V to +6V
OUT to GND ................................................-0.3V to (VIN + 0.3V)
Maximum Continuous Switch Current .....1.2A (internally limited)
OUT Short Circuit to GND ..........................................Continuous
Continuous Power Dissipation (TA = +70°C)
10-Pin MAX (derate 5.6mW/°C above +70°C) ............444mW
Operating Temperature Range
MAX1693EUB/MAX1693HEUB/
MAX1694EUB ..................................................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
V ON (ON) = GND (VIN)
IOUT = 0
ISINK = 1mA, VIN = 3V
V ON (ON) = VIN or GND
(Note 1)
VIN = 2.7V to 3.6V
VIN = 2.7V to 5.5V
TA = +25°C
V ON (ON) = VIN = VOUT = 5.5V (VON = GND)
Rising edge, 100mV hysteresis
V ON (ON) = VIN (GND)
VIN = 5.5V,
VOUT = GND
OUT shorted to GND, MAX1693/(MAX1693H)
only (Note 2)
CONDITIONS
V
0.4
VOL
FAULT Output Logic Low
Voltage
A
±1
ON (ON) Input Leakage
V
2
VIH
ON (ON) Input Logic High
Voltage
V
0.8
VIL
ON (ON) Input Logic Low Voltage
mA
500
700
ISC
Continuous Short-Circuit
Current Limit
A
35
IQ
14
25
V
2.7
5.5
VIN
Operating Voltage
Quiescent Current
mA
700
850
1000
ILIMIT
Current Limit
m
72
150
RON
On-Resistance
125
60
90
A
0.001
1
Off-Supply Current
V
2.0
2.6
UVLO
Undervoltage Lockout
0.01
2
A
15
Off-Switch Leakage
UNITS
MIN
TYP
MAX
SYMBOL
PARAMETER
Timer not running
Timer running
TA = +25°C
TA = 0°C to +85°C
VIN = 4.4V to 5.5V
VIN = 3V
VIN = VFAULT = 5.5V
A
1
FAULT Output High Leakage
Current
From overcurrent condition to FAULT assertion
ms
710
13
tFB
Fault-Blanking Timeout Period
VIN = 5V, COUT = 150F, RL = 15
,
from ON (ON) driven low (high) to 50% full VOUT
ms
1
Start-Up Time
ILOAD = 400mA
s
36
20
tOFF
Switch Turn-Off Time
ILOAD = 400mA
s
80
200
tON
Switch Turn-On Time
°C
165
Thermal Shutdown Threshold
TA = 0°C to +85°C
VIN = 3.7V to 5.5V
2.4